Waterproofing decides the lifespan, not the tile
Most bathroom failures in Greek apartment buildings trace back to one decision made in the first two days of the job: how the wet zones were tanked before tiling. A tile finish can look identical whether the membrane underneath is continuous and taped at every junction, or patchy and reliant on grout to keep water out. The difference only shows up eighteen months later, in the ceiling of the flat below.
We tank every wet zone as a continuous system — floor, upstands and shower walls to at least 1.8 metres — with taped corners, pipe collars sealed at penetration points, and a flood test held for a minimum of 24 hours before any tile is fixed. This is documented with photographs and a signed record, because it is the one part of the job you cannot inspect once the room is finished.
Everything above the membrane is decoration. Everything in the membrane is the actual bathroom.